Kieker 1.9

kieker.tools.opad.record
Class NamedDoubleRecord

java.lang.Object
  extended by kieker.common.record.AbstractMonitoringRecord
      extended by kieker.tools.opad.record.NamedDoubleRecord
All Implemented Interfaces:
Serializable, Comparable<IMonitoringRecord>, IMonitoringRecord, IMonitoringRecord.BinaryFactory, IMonitoringRecord.Factory

public class NamedDoubleRecord
extends AbstractMonitoringRecord
implements IMonitoringRecord.Factory, IMonitoringRecord.BinaryFactory

This class represents responsetime data from a measured application, stored as an double value.

Since:
1.9
Author:
Tom Frotscher
See Also:
Serialized Form

Nested Class Summary
 
Nested classes/interfaces inherited from interface kieker.common.record.IMonitoringRecord
IMonitoringRecord.BinaryFactory, IMonitoringRecord.Factory
 
Field Summary
static int SIZE
           
static Class<?>[] TYPES
           
 
Fields inherited from class kieker.common.record.AbstractMonitoringRecord
TYPE_SIZE_BOOLEAN, TYPE_SIZE_BYTE, TYPE_SIZE_CHARACTER, TYPE_SIZE_DOUBLE, TYPE_SIZE_FLOAT, TYPE_SIZE_INT, TYPE_SIZE_LONG, TYPE_SIZE_SHORT, TYPE_SIZE_STRING
 
Constructor Summary
NamedDoubleRecord(ByteBuffer buffer, IRegistry<String> stringRegistry)
           
NamedDoubleRecord(Object[] values)
          Creates an Instance of this class based on a single object array.
NamedDoubleRecord(String application, long timest, double response)
          Creates an instance of this class based on the parameters.
 
Method Summary
 String getApplication()
          Returns the application name.
 int getSize()
          This method should deliver the size of a binary representation of this record.
 long getTimestamp()
          Returns the timestamp.
 double getValue()
          Returns the Value.
 Class<?>[] getValueTypes()
          This method should deliver an array with the classes of the single values for the record.
 void initFromArray(Object[] arg0)
          Deprecated. This record uses the IMonitoringRecord.Factory mechanism. Hence, this method is not implemented.
 void initFromBytes(ByteBuffer buffer, IRegistry<String> stringRegistry)
          Deprecated. This record uses the IMonitoringRecord.BinaryFactory mechanism. Hence, this method is not implemented.
 Object[] toArray()
          This method should deliver an array containing the content of the record.
 void writeBytes(ByteBuffer buffer, IRegistry<String> stringRegistry)
          This method should deliver an byte array containing the content of the record.
 
Methods inherited from class kieker.common.record.AbstractMonitoringRecord
checkArray, classForName, compareTo, createFromArray, createFromByteBuffer, createFromStringArray, equals, fromStringArrayToTypedArray, getLoggingTimestamp, hashCode, setLoggingTimestamp, toString, typesForClass
 
Methods inherited from class java.lang.Object
getClass, notify, notifyAll, wait, wait, wait
 

Field Detail

SIZE

public static final int SIZE
See Also:
Constant Field Values

TYPES

public static final Class<?>[] TYPES
Constructor Detail

NamedDoubleRecord

public NamedDoubleRecord(String application,
                         long timest,
                         double response)
Creates an instance of this class based on the parameters.

Parameters:
application - Application that is the source of the data
timest - Timestamp
response - Responsetime stored in this record

NamedDoubleRecord

public NamedDoubleRecord(ByteBuffer buffer,
                         IRegistry<String> stringRegistry)
                  throws BufferUnderflowException
Throws:
BufferUnderflowException

NamedDoubleRecord

public NamedDoubleRecord(Object[] values)
Creates an Instance of this class based on a single object array.

Parameters:
values - Object array containing the applicationname, timestamp and responsetime
Method Detail

getValueTypes

public Class<?>[] getValueTypes()
This method should deliver an array with the classes of the single values for the record.

Specified by:
getValueTypes in interface IMonitoringRecord
Returns:
The types of the values. This returned array should be treated readonly.
See Also:
IMonitoringRecord.toArray()

initFromArray

@Deprecated
public void initFromArray(Object[] arg0)
Deprecated. This record uses the IMonitoringRecord.Factory mechanism. Hence, this method is not implemented.

This method should initialize the record based on the given values. The array should be one of those resulting from a call to IMonitoringRecord.toArray().

Specified by:
initFromArray in interface IMonitoringRecord
Parameters:
arg0 - The values for the record.

toArray

public Object[] toArray()
This method should deliver an array containing the content of the record. It should be possible to convert this array later into a record again.

Specified by:
toArray in interface IMonitoringRecord
Returns:
An array with the values of the record.

getApplication

public String getApplication()
Returns the application name.

Returns:
Apllication name

getTimestamp

public long getTimestamp()
Returns the timestamp.

Returns:
Timestamp

getValue

public double getValue()
Returns the Value.

Returns:
Value

writeBytes

public void writeBytes(ByteBuffer buffer,
                       IRegistry<String> stringRegistry)
                throws BufferOverflowException
Description copied from interface: IMonitoringRecord
This method should deliver an byte array containing the content of the record. It should be possible to convert this array later into a record again.

Specified by:
writeBytes in interface IMonitoringRecord
Parameters:
buffer - The used ByteBuffer with sufficient capacity
stringRegistry - Usually the associated MonitoringController
Throws:
BufferOverflowException - if buffer not sufficient

initFromBytes

@Deprecated
public void initFromBytes(ByteBuffer buffer,
                                     IRegistry<String> stringRegistry)
                   throws BufferUnderflowException
Deprecated. This record uses the IMonitoringRecord.BinaryFactory mechanism. Hence, this method is not implemented.

This method should initialize the record based on the given values. The array should be one of those resulting from a call to IMonitoringRecord.writeBytes(ByteBuffer, IRegistry).

Specified by:
initFromBytes in interface IMonitoringRecord
Parameters:
buffer - The bytes for the record.
stringRegistry - The Registry storing the strings.
Throws:
BufferUnderflowException - if buffer not sufficient

getSize

public int getSize()
Description copied from interface: IMonitoringRecord
This method should deliver the size of a binary representation of this record.

Specified by:
getSize in interface IMonitoringRecord
Returns:
The size.

Kieker 1.9